Sherlock 5-Second Leak Detector
Sherlock 5-Second Leak Detectors are used for detecting leaks in pipe joints, tube connections, tanks or any system under gas or air pressure. They are very easy to use, simply wipe surface to be tested with a brush or dauber, squirt on with a squeeze bottle or spray with a trigger sprayer. Small leaks form white foam in 5 to 60 seconds. Large leaks form large bubbles almost instantly.
Shipped only in unbreakable containers.
Sherlock fluids can be packaged in:
- 4 and 8 ounce squeeze bottles
- 8 ounce dauber bottles
- 16 ounce trigger sprayers
- single gallons packed 4 or 6 gallons per carton
- 5 gallon pails
- 55 gallon drums
Low-Temp
The first and best chemical type leak detector designed for finding the air and gas leaks at subfreezing temperatures down to -10 degrees Fahrenheit.
Regular
Specially formulated chemical type leak detection fluid for locating leaks in pressurized gas and air systems, except oxygen, in temperatures above freezing.
Type CG
For leak testing lines, cylinders and tanks carrying pure oxygen and compressed gases. Compatible with oxygen either high or low pressure as well as other gases.
Extra Low-Temp
The most effective chemical type leak detector designed for finding air and gas leaks at temperatures down to -55 degrees Fahrenheit.
Type I & Type II
For oxygen leak-testing. Products that are made to meet
MIL-PRF-25567E.
Type I - For use from +35 degrees Fahrenheit to +160 degrees Fahrenheit
Type II - For use from -65 degrees Fahrenheit to + 35 degrees Fahrenheit
Type I & Type II are neutral solutions formulated for leak-testing lines, cylinders and tanks carrying pure oxygen, but also widely for testing fuel tanks, pneumatic systems - in fact any product or system that can be leak tested with air or gas pressure. Type I and Type II contain no oil, grease or any other ingredient that could combine with pure oxygen to form either a flammable or explosive mixture. Thoroughly tested and approved by both governmental and commercial laboratories. Apply to connection or surface suspected of leaking and watch for bubble clusters. Fine leaks form white foam which builds up for ten minutes or more, making detection sure and simple. Large leaks form clusters of large bubbles immediately on application.
Type I and Type II are available in many different sizes such as:
- 4 and 8 ounce squeeze bottles
- 8 ounce bottle dauber cap
-single gallons packed 4 or 6 gallons per carton
- 5 gallon pails
55 gallon drums
Type I and Type II dry clean and leave no greasy residue. They are extremely accurate.
Type I
Type II
Seamtest Concentrate
Three low-cost fluids for leak-testing tanks, cylinders, valves, compressors, gas appliances, or any other part or system that can be leak tested with air or gas pressure in air or under water.
SEAMTEST is widely used by hundreds of manufacturers... tank companies, refrigeration equipment companies, valve manufacturers, automobile producers and a host of others making a wide range of products.
SEAMTEST Products are available to be packaged as follows:
- single gallons with either 4 or 6 gallons per carton
- 5 gallon pails
- 55 gallon drums
SEAMTEST Regular is used for testing air above freezing. It is a foaming concentrate mixed usually 4 ounces of concentrate in 5 gallons of water, but may be used at higher concentrations depending upon application. Mixed fluid is applied to test surface with brush or swab. Large leaks instantly form large bubble clusters. Very small leaks form clusters of white foam which builds up for several minutes, making pinpointing of leaks easy and certain. Contains no oil, grease fatty acids or lgepal. No need to remove before painting. LOW-COST-- less than 15 cents per gallon of mixed fluid
SEAMTEST Regular Halogen Free is available upon request
SEAMTEST, LOW TEMP is similar to SEAMTEST REGULAR except for use below freezing. Dilution depends upon operating temperature, 32 degrees Fahrenheit to 15 degrees Fahrenheit mix 1 gallon of concentrate to 4 gallons of water. Below 15 degrees Fahrenheit mix 1 gallon of concentrate to 2 gallons of water. Apply the same way as SEAMTEST REGULAR.
Keep brush sopping wet do not work up a lather.
SEAMTEST, TYPE U is a non-foaming concentrate used for leak testing, small tanks, compressors etc. under water. Recommended dilution is 2 ounces of concentrate for each five gallons of water in testing tank. Type U greatly increases accuracy and efficiency of immersion testing. Tiny leaks that will not show up in water will form a clearly visible thread of minute bubbles when Type U is added to the testing water. Great time saver.